粉丝1911获赞6721

now hoss is made pro being on their mills really simple, but if something does go wrong where do we look well one of my favorite quotes is that if you hear hoofbeats think horse not zebra what that means is look at the most common things first, so when we're looking at common root causes of probing problems, bad batteries or right at the top of our list so how can we tell if we've got a bad battery now if i was at home and digging through the double a batteries in my kitchen junk drawer i would grab a voltmeter and check and see if the voltage is low, but these batteries that we're using our probes are nothing like that their lithium thio nail chloride batteries these batteries have a shelf like that's measured in decades not months and they wear down in a very unique way the alkaline batteries that we're all used to wear down over time if i leave my flashlight on for a couple hours it might read one point one volts instead of one point five volts now our ltc batteries are not like that they're going to hold three point six volts right up until the moment they die now why is this important well, what i'm trying to convey here is that just because you get 3.6 volts on your volt meter when measuring an ltc battery that doesn't necessarily mean that it's a good battery i know i know you don't believe me you trust your voltmeter well, let me show you a pile of batteries and explain how this works now i've placed a bunch of use pro batteries onto this bench now all these are bad i've had electrical engineering check them under load with equipment that you and i don't have now what you and i do have is a volt meter and most of these batteries still read 3.6 volts only three of them have no voltage on them at all let me grab a couple of these batteries we'll put them into a spindle probe and show you what we get now if i put these batteries in and i get a flashing red light or a flashing red green blue light where it cycles that over and over again that means these batteries are bad and it looks like i'm getting a flashing red green blue these batteries that measure three point six volts just a minute ago are showing up as bad now if we've been in the machine actually in cycle and we got a low battery alarm it would typically flash green and blue so you can get all kinds of errors if we put bad batteries into our spindle probe so if you have any probe problems, any flashing lights and you're not sure what the problem is change your battery and when installing the new battery be sure to write the date on it that way you'll know when it was installed now even when the probe isn't being used it's just in standby mode it's still using some electricity now reneshaw tells us that our spindle probe last around 250 days max even when it's not being used it can only left about eight months now the table probar ots tool setter the batteries in there last around ten months even if it's not being used, so if you're getting any kind of flashing lights in your probe stops working change the batteries now when you change your batteries be sure that you don't trigger that probe if you hold down the probe while changing the batteries that could put it in a setup mode and you could mess up your settings now that's not likely remember think horse not zebra now if you've changed out the battery and you're still having some kind of probing problem the next thing we want to look at the next most common culprit is going to be our calibration now we've got really good instructions on how to calibrate your probe on the host diy site so you can check those out at diy dot hos cnc com just search for probing and look under procedures now some tips and tricks on calibrating your probe always do things in order you want to calibrate the table probe first then you're gonna calibrate the length of your spindle probe and finally you're gonna end with calibrating the diameter on your spindle probe if you did things out of order for head to reset during this process we could have messed something up the machine might think that it's done calibrating when it's not if that's happened to you and you just can't get through the calibration process go to the macros page clear your macro variables and start over that'll refresh the entire system and let us recalibrate from scratch now if we've changed the battery and we've tried to calibrate the probe and we're still having problems maybe we're getting alarms or maybe we couldn't even finish the calibration process it's time to look at our probe in macros it's possible that they've been corrupted or deleted all together you can download the probing macros for your machine by going to the diy site again search for probing and then go to the download section if you have a wired table pro, you're gonna download version one point nine of those probing macros if you've got a classic control with a wireless table pro, you're gonna download version three point o and if you've got a next generation control an n g c, you're gonna download download version 3.7 or higher now loading these macros is pretty simple these are 9000 programs so we need to turn setting 23 9000 program edit lock off next, we just load these onto the control like you would any other program on a classic control you copy them into memory on their way in it's gonna self extract into all these nine thousand programs all of our probing macros, if you've got a next gen control those probing macros are gonna be placed into the zero nine thousand folder well hopefully we solve your problem today's video should have covered about ninety five percent of the root causes of probing issues we change out the battery be sure to write the date on the battery then we calibrate our probes be sure to clear out the macro variables and calibrate the probe in order table probe spindle, probe length spindle probe diameter if we still had a problem we told you that you can download the new macros probing macros from the host diy site now if you're still having problems we've made another video that covers manually checking your probe and also tells you how to set your trigger logic settings on those rena shop probes that's it and thanks for watching this past tip of the day。

这个没没反应启动。没有启动的那个我煤气已经打开了。这个煤气我已经打开了。

红外探真器不报警怎么办?变红灯机器不报警,用手体调节上方感应器,直至绿灯熄灭。调节上面感应器按钮,直至绿灯熄灭。 探真报警维修完成。想了解更多,横击维修常识,点个关注!

老姜出马,一个顶俩。大家好,我是姜胖,上期呢,讲到这个 wifi 探针可以检测到手机的麦克地址,有人会问了,不就一个麦克地址吗?让人知道了又能怎么样,对不对? 呃,现在呢,这个年代谁没实名注册过几个 app, 或者注册过几个网站,咱们这个个人信息呢,早就进入了人家的大数据库了,就包括你的这个姓名,年龄、电话、职业等等等等,这里面呢,就包括一个麦克地址, 正常在线上大数据库,这个麦克地址他是一条无用的信息,但是结合这个 wifi 探真呢,他就能知道这个麦克地址对应的人名。经常去哪?比如江胖经常去这个各个城市,然后在这个机场, 车站,各个城市的酒店,这可能就是一个经常出差的人,就可以给他推送一些打折的机票,酒店这类的信息。呃,江胖呢,又天天去这个什么天天去游泳馆呢,天天去健身房啊,给他推一些这些健身器材呀,健身的这些东西。 呃,这个呢,还是好的,只是呢,做一些精准的营销。还有呢,这个也可以为这个诈骗的犯罪活动提供这个方面, 你比如说我就接到过这个退机票的诈骗电话,因为我经常去机场啊,他给我打这种诈骗电话,总比一个从没去过机场的人打这个电话成功率要高很多,对吧? 呃,还有呢,除了 wifi 探针,还有各个商家提供的这些免费的 wifi 呀, 也都可以采集这个麦克力,所以说呢,咱们去哪的时候,免费的 wifi 能不用也就尽量不用了。好了,今天就先讲到这里,我是姜胖,头发短见识多,下期我们接着说。

一般有三个原因,第一烫针和炉壳线的螺丝松动,第二,烫针,第三线路板。接下来我来教大家怎么判断。一般烫针的话都是在机器外壳的里面,首先我们先把外壳拆下来, 现在外壳已经拆下来了,这一根就是碳针,然后这根是乳壳线,我们先检查一下连接的螺丝有没有松动,如果螺丝松动的话,那拧紧一下,我们再重新开机看一下他这个问题是不是就已经解决了。 如果两个螺丝都没有松动的情况下,那我们来判断一下是烫针的问题还是电脑控制面板的问题。那我们可以先把这根卢克线的螺丝拆掉,把线拿出来拉到这个烫针上面,然后再开机看一下他会不会停, 然后我们找到一把合适的扳手,把这个螺丝拆下来,把烫针上面的这个小螺丝拧下, 然后再把这根线五颗线拉上去,再粘起来,这样扣住就可以了。然后我们再开机看一下这样的情况下他会不会停,如果他会停了,那说明是这个探针的问题,如果不会停的话,那就是线路板的问题,线路板问题的话,我们可以先把这个盖子拆掉, 放上去一点,方便操作,然后用手机先拍个图片,把上面的线路拍一个,再把边上的这四个螺丝卸下来,把它换上去,然后再重新接线就可以了。是烫针问题的话,那我们把烫针拆下来,先把这根线先把它拆掉, 拿下来之后我们拧最下面的这个金色的螺丝,最下面这一颗拧这个螺丝,把它拧下来, 这个就是碳针,我们拧下来先检查一下他脏不脏,如果脏的话我们可以用清洁球啊把它刷一下,然后再重新装回去。碳针装回去还是不行的话,那就只有换一根碳针了,你学会了吗?


大家好,咱们聊聊燃烧器燃烧器故障值离子碳真。这个现场就是典型的因为离子碳真错位而造成的熄火,大家可以看看。而且长时间不使用燃烧器,可能使离子碳真受潮。 我们可以先使用砂纸轻轻打磨一下,然后调一下离子碳针的位置。谢谢大家点赞关注。

三、坐标探针教验不成功,软件提示角度教验超出限制。那么我们思考主要原因又是什么呢?一、红宝石球和标准球是否清洁,我们可以用无纺布加酒精进行擦拭。二、侧针和标准球是否安装牢固? 探针较验前需用扳手适当力度紧固,防止松动造成对较验结果的影响。三、侧针定义错误,就是说我们的红宝石球直径本身定义错误,分别检查后再次较验即可。

我们在使用烫针过程中,因为操作不当或异常情况导致烫针断裂, 我们就要对探针进行更换和嘲笑。首先我们先用扳手把探针拆掉,拆掉之后我们重新换上新的探针, 然后通过切换表查看烫针针头的跳动情况。当前误差五个丝,我们通过下面三个螺丝进行微调好,现在目前还有两个 mu 已经达到可接受的范围。 下一步我们把探针移动到标准球上方大约十毫米左右的位置,然后点击 手动模式,在屏幕上我们选择探测功能,通过左右键找到校选 ts, 在屏幕上选择标准球的选项,查看参数表,并设定相应的参数。标准球的直径我们在这里输入二十五,安全距离是毫米 测量点设定四个,其他参数我们保持默认。然后我们把净给力设定成五十左右,再按启动键,此时的机场进入自动检测功能, 整个过程大约要持续三到四分钟。当前主要是检测探灯的 xy 位移量和探头的 半径。另外要特别注意检测此项需要先检测探针的长度,大家可以先关注我,后续我们会持续的更新 好。检测停止之后,我们点击屏幕上的, ok, 在点击之前我们先看一下这里的仓数以及位移量。原来探征半径显示是一点九二九四, x, 配音量负零点零零零三, y, 配音量零点零零二七。 调校之后的坦征半径是幺点九二九三, x 的偏音量是负零点零零三, y 的偏音量是零点零零二七。我们发现当前 片一亮是没有误差,那么半径是有零点一个 miu 的误差, 最后我们点击 ok, 完成检测功能。

大家好,这里是安泰测试啊,今天和大家介绍一下试播器的入门技术使用,要使用试播器来测量我们的波形的话,那么是要使用工具的,那么这个工具呢,就是我们试播器会用到的一个探头啊, 首先呢我给大家介绍一下这个探头,这个是我们探头的一个接口啊,就接到试播器的,他是 bnc 的一个接头,那我给大家介绍一下,就是我们的这个鳄鱼家, 这个呢是鳄鱼家式石波器,这个探头用来接地的,那么他的这个地呢,其实是和我们石波气的地是接在一起的。 介绍到这的话,我给大家就是啊着重提一下这个使用过程中的一个问题,就是说有些同学呢可能会想,哎,我把这个鳄鱼家的呃这个地给他接到信号上行吗?啊 啊,这样的话,我可以测两个信号,测插分信号可不可以呢?我告诉大家这样测是不可以的啊,因为这个鳄鱼浆呢是和他的施波器的 d 接在一起的,那么如果我们用两个通道两个探头来测的话,如果你把两个鳄鱼加都接到,同时接到两个信号, 因为他们是接到试播期的地的,那么他们是供地的,这样的话就会造成啊,这个鳄鱼家的短接,那么会对我们这个所测量的这个信号造成一定的损坏,所以说大家千万要注意到这一点。 另一个呢就是我们的一个识播区的这个探头啊,首先的话,大家可以看到这是有一个挂钩的,我们可以把这个挂钩挂在到我们的被侧键上啊,被侧键的一个被侧点上,用来方便我们的一个测量,那么有些同学呢可能用的就是说,嗯,这种 pcb 的板子,那么上面 啊不太方便挂这个挂钩,那么呢我们就可以用啊,这个我们试播器可以把它取下来,大家可以看到这是一个探针,那么呢大家想哎,那你这个探针你取下之后,这个鳄鱼夹对吧,有时候特别长对吧,不方便我这个 接地怎么办,对不对?那么这时候呢,大家可以其实是把这个阿姨家是可以取下来的啊,大家可以看到取下来啊,我们只需要接一个我们的接地弹簧就可以了啊,在这个地方套一个接地弹簧,那么其实也是可以代替我们的这个接地的作用的,也是可以的。 接下来呢给大家介绍一下如何使用试播器啊,测量一个简单的信号。首先呢在使用试播器测量信号之前呢,我们是要对啊,我们所使用的这个工具,也就是我们的探头来进行一个 长的较准,这样才才不会使我们被测信号啊,出现一些比如说我们测量生活过程中遇到的一些啊,信号的一些积变,对吧变形,或者说一些其他一些我们并不是我们所认识的一些奇怪的波形啊,以免啊为了测试的一个准确性,所以呢大家先对这个进行一个较准, 接下来我给大家演示一下,首先把试播器,把试播器和我们的探头连在一起啊,接下来呢 就是用我们石波器自带的这个自剪信号的啊,每一款石波器都是有这个,大概都在这个位置啊,大家可以找一下,这是一个标准的一个自剪信号,我们用看头把它接上, 接下来大家看到哎石波器上并没有波星出现,为什么呢?因为我们的这个通道铁是没有打开的,嗯,按一下他 啊,这个时候呢,我们按一下这个凹凸,那么大家可以看到这个波形啊,在我们的试播期上其实是已经显示出来了, 大家可以看到这个呢,我们的这个标准的字眼信号是一个方波,但是大家可以看到他其实是有过冲的,为什么会出现这种情况,就是因为啊我们探头的这个补偿没有调整好,所以会造成我们测量的这个信号出现了一定的基变。 接下来我给大家演示一下怎么调,那么我们的探头呢,其实是在这个位置是有一个啊补偿电容的,大家可以看到 大家可以看到这个位置就是调节我们探头的一个补偿电容,刚才那个界面就是有过冲,大家看 通过这个位置来对探讨进行一个补偿的调节。接下来给大家看一下如何调节, 大家可以看到这个是我们的一个补偿探头的一个调节方位,接下来呢我们通过啊旋转这个旋钮,大家可以看到 这个波形是有变化的,那么呢我们把它调到一个正常方波的一个形状,这样子就可以了啊, 这个的话就是我们经常会遇到的一种情况,那么这个就是我们一个探头的一个补偿的调节。

今天我们把这个解密软件的一个连接线啊做了一个简单的优化,原先呢是这种先被夹子的很多小伙伴反映去夹了个芯片 甲上,芯片他会打滑或者说很难接触到,导致解密了操作起来比较困难啊。这个是原先一个老的设计,甲上之后呢,可能手一松啊,贴一点点就不行了,或者甚至于打滑就跳出来了。然后呢我们设计了个这小玩意, 这个玩意呢,呃,叫碳针,然后它是带有一个伸缩的啊,可以压下, 然后这个最底端呢,它是采用那种八爪针啊,这种小的一个特别结的一个东西,能够更好的跟芯片一个接触, 因为他有一个伸缩量,所以呢当我们这个芯片啊,比如说我们斜一点点的话,他也是通过伸缩量可以接触到,往左右斜啊,都是可以同时接触到芯片上面。 然后呢,呃,这是我们芯片那个解密的一个连接线啊, usb 一头连到电脑,另外一头呢就通过了我们这个探针来进行一个连接解密, 然后简单演示一下啊,首先这个芯片的话呢,不同主板不同的芯片在说明书上面都有明确的标识,然后呢 这里红线是一角,对应我们以前这个夹子的一角啊,是一样的,然后一角的话呢,对应我们芯片上面这个小圆点啊,这个小圆点一角,那我们就转个面 挡灭过了,然后直接对到这个芯片这里一插,往下一压就可以了啊,往下一压的话呢,这个指示灯就亮了啊,我们把它抬起来, 他家的话,芯片就那个指示灯就灭了,然后这个的话呢一压就可以啊,然后我们主要晃动他都能够比较好的一个接触到啊,不像芯片夹子一样的啊,稍微一点点推动,这里是就解解不了密啊,这个的话呢,我们稍微晃动一下啊,不影响, 只要这个灯是绿的啊,亮了就可以了,然后解密就直接操作点一下解密软件就可以了啊,这里直接点击解密就行了。 这是这个东西经过老王最近的一段时间使用啊,确实挺好用的,比那个铅笔夹要方便多了, 以后买解密软件的话呢,我们默认的话呢,就用这个啊发这个了,芯片夹子的话呢,慢慢的就淘汰掉了, 如果以前有买过的啊,想需要更换的话呢,就联系老王进行一个更换就可以,但是更换会有一个几十块钱的费用啊啊,有需要的话可以去老王的这个店铺看一下。

今天来处理一张探真卡水平不好的问题,动手拆卡干活。首先显微镜检查一下探卡状态,看上去状态不错,处理一下还能用上。我的大宝贝磨真机,他从来没让我失望过。 开始操作还是全自动的好呀,这个水平差的可不是一星半点呀,看来还是要加强质量管控。水平磨好了,然后进行电解处理,上机看看修复的怎么样。 中间的过程就不一一展示了,因为比较麻烦,就当保密还不错,稍微有点偏在管控范围内,就这样使用吧。